IHEP OpenIR  > 院士  > 期刊论文
ELECTROMAGNETIC CALORIMETER WITH THIN GAP WIRE CHAMBERS
Chen B(陈彬); Zhu PP(朱佩平); Shu H(舒航); Liu YJ(刘宜晋); Yuan QX(袁清习); Wang JY(王佳怡); Huang WX(黄万霞); Wu ZY(吴自玉); CHEN, C; CHEN, HS; FUKUSHIMA, M; LECOULTRE, P; LI, HT; LIU, JB; TANG, XW; TUNG, KL; WANG, JH; WU, RJ; YOSHIMURA, Y; ZHUANG, HL
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
1994
卷号351期号:2-3页码:330-335
学科分类Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy
DOI10.1016/0168-9002(94)91360-9
通讯作者KEK NAT LAB HIGH ENERGY PHYS,TSUKUBA,IBARAKI 305,JAPAN ; ETH ZURICH,CH-8093 ZURICH,SWITZERLAND
文章类型Article
英文摘要In this paper we report about the experimental results obtained in a beam test of a gas sampling EM calorimeter. The module consists of 20 thin gap (30 mm) multiwire chambers as active elements, interleaved with brass absorber plates of 12 mm thickness or 0.84 radiation length. The KEK electron beam was tuned to energies of 0.5, 1.0, 2.0, 3.0, 4.0 GeV. The construction and performances of the chamber, the assembling of the module, the experimental setup and data acquisition system are briefly described. The energy resolution of the module is found to be 25%/root E (E in GeV). In the range of measured energies, good linearity of the energy response is obtained. The longitudinal development of EM shower, the relation between energy resolution and thickness of the absorber as well as the high voltage of the chamber are studied. The effect of incident position of the beam on the performance of the module is also given.
类目[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy
研究领域[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics ; Spectroscopy
原文出处查看原文
语种英语
WOS记录号WOS:A1994PU86500011
引用统计
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/237012
专题院士_期刊论文
中国科学院高能物理研究所_粒子天体物理中心
中国科学院高能物理研究所_多学科研究中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Chen B,Zhu PP,Shu H,et al. ELECTROMAGNETIC CALORIMETER WITH THIN GAP WIRE CHAMBERS[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,1994,351(2-3):330-335.
APA 陈彬.,朱佩平.,舒航.,刘宜晋.,袁清习.,...&ZHUANG, HL.(1994).ELECTROMAGNETIC CALORIMETER WITH THIN GAP WIRE CHAMBERS.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,351(2-3),330-335.
MLA 陈彬,et al."ELECTROMAGNETIC CALORIMETER WITH THIN GAP WIRE CHAMBERS".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 351.2-3(1994):330-335.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
3235.pdf(372KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[陈彬]的文章
[朱佩平]的文章
[舒航]的文章
百度学术
百度学术中相似的文章
[陈彬]的文章
[朱佩平]的文章
[舒航]的文章
必应学术
必应学术中相似的文章
[陈彬]的文章
[朱佩平]的文章
[舒航]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 3235.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。