Thermal analysis for wire scanners in the CSNS Linac | |
Yang T(杨涛); Fu SN(傅世年)![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | |
2014 | |
发表期刊 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (IF:1.362[JCR-2016],1.211[5-Year]) |
ISSN | 0168-9002 |
EISSN | 1872-9576 |
卷号 | 760页码:10-18 |
摘要 | 3 MeV H beam from the Radio Frequency Quadrupole (RFQ) will be accelerated to 80 MeV in the CSNS (China Spallation Neutron Source) linear accelerator (Linac). The wire scanner is used to measure the transverse beam profile and the emittance, and the carbon or tungsten wire is considered to use. Thermal analysis of the wire scanners in the Linac is presented in this paper. The maximum temperature (T,) of the wire decreases as the beam energy increases, and we also calculate the influence of all possible parameters on T-m. T-m, of carbon wire is significantly lower than tungsten wire if both the beam parameters and wire geometric parameters are set to the same, which can be attributed to its higher heat capacity and radiant emissivity. In addition, we present the results of sublimation rate of the wire, which show that tungsten wire has a much lower evaporation rate than carbon wire in the same temperature, which can be attributed to the different vapor pressures of the two materials. To limit the thermionic emission, the maximum beam frequency approximately has an exponential relationship with beam rms size at a certain beam pulse width. (C) 2014 Elsevier B.V. All rights reserved. |
关键词 | CSNS Linac The maximum temperature Beam and geometric parameters Wire sublimation Restraining the thermionic emission |
学科领域 | Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy |
DOI | 10.1016/j.nima.2014.05.061 |
收录类别 | SCI ; INSPIREHEP ; ADS |
语种 | 英语 |
WOS记录号 | WOS:000338350500003 |
ADS Bibcode | 2014NIMPA.760...10Y |
ADS URL | https://ui.adsabs.harvard.edu/abs/2014NIMPA.760...10Y |
ADS引文 | https://ui.adsabs.harvard.edu/abs/2014NIMPA.760...10Y/citations |
INSPIRE ID | 1304772 |
INSPIRE URL | https://inspirehep.net/literature/1304772 |
引用统计 | 正在获取...
被引频次:3 [INSPIRE]
被引频次:3 [ADS]
|
文献类型 | 期刊论文 |
条目标识符 | https://ir.ihep.ac.cn/handle/311005/225218 |
专题 | 加速器中心 中国科学院高能物理研究所_中国散裂中子源 |
推荐引用方式 GB/T 7714 | Yang T,Fu SN,Xu TG,et al. Thermal analysis for wire scanners in the CSNS Linac[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2014,760:10-18. |
APA | 杨涛.,傅世年.,徐韬光.,Yang, T.,Fu, SN.,...&李芳.(2014).Thermal analysis for wire scanners in the CSNS Linac.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,760,10-18. |
MLA | 杨涛,et al."Thermal analysis for wire scanners in the CSNS Linac".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 760(2014):10-18. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[杨涛]的文章 |
[傅世年]的文章 |
[徐韬光]的文章 |
百度学术 |
百度学术中相似的文章 |
[杨涛]的文章 |
[傅世年]的文章 |
[徐韬光]的文章 |
必应学术 |
必应学术中相似的文章 |
[杨涛]的文章 |
[傅世年]的文章 |
[徐韬光]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论