R&D of the CEPC scintillator-tungsten ECAL | |
CEPC Calorimeter Working Grp | |
2018 | |
Source Publication | JOURNAL OF INSTRUMENTATION
![]() |
ISSN | 1748-0221 |
Volume | 13Pages:C03024 |
Subtype | Article; Proceedings Paper |
Abstract | The circular electron and positron collider (CEPC) was proposed as a future Higgs factory. To meet the physics requirements, a particle flow algorithm-oriented calorimeter system with high energy resolution and precise reconstruction is considered. A sampling calorimeter with scintillator-tungsten sandwich structure is selected as one of the electromagnetic calorimeter (ECAL) options due to its good performance and relatively low cost. We present the design, the test and the optimization of the scintillator module read out by silicon photomultiplier (SiPM), including the design and the development of the electronics. To estimate the performance of the scintillator and SiPM module for particles with different energy, the beam test of a mini detector prototype without tungsten shower material was performed at the E3 beams in Institute of High Energy Physics (IHEP). The results are consistent with the expectation. These studies provide a reference and promote the development of particle flow electromagnetic calorimeter for the CEPC. |
Conference Title | Conference on Calorimetry for the High Energy Frontier (CHEF) |
Conference Place | Lyon, FRANCE |
Keyword | Calorimeters Calorimeter methods Large detector systems for particle and astroparticle physics |
DOI | 10.1088/1748-0221/13/03/C03024 |
Indexed By | SCI ; EI ; CPCI |
Language | 英语 |
WOS Research Area | Instruments & Instrumentation |
WOS Subject | Instruments & Instrumentation |
WOS ID | WOS:000427226600005 |
EI Accession Number | 20181504997478 |
ADS Bibcode | 2018JInst..13C3024D |
inspireid | 1667760 |
Citation statistics |
Cited Times:1 [INSPIRE]
Cited Times:1 [ADS]
|
Document Type | 期刊论文 |
Identifier | http://ir.ihep.ac.cn/handle/311005/285725 |
Collection | 实验物理中心 |
Affiliation | 中国科学院高能物理研究所 |
First Author Affilication | Institute of High Energy |
Recommended Citation GB/T 7714 | CEPC Calorimeter Working Grp. R&D of the CEPC scintillator-tungsten ECAL[J]. JOURNAL OF INSTRUMENTATION,2018,13:C03024. |
APA | CEPC Calorimeter Working Grp.(2018).R&D of the CEPC scintillator-tungsten ECAL.JOURNAL OF INSTRUMENTATION,13,C03024. |
MLA | CEPC Calorimeter Working Grp."R&D of the CEPC scintillator-tungsten ECAL".JOURNAL OF INSTRUMENTATION 13(2018):C03024. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.