Tykhonov, A; Ambrosi, G; Asf; iyarov, R; Azzarello, P; Bernardini, P; Bertucci, B; Bolognini, A; Cadoux, F; D'Amone, A; De Benedittis, A; De Mitri, I; Di Santo, M; Dong, YF![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | |
2018 | |
Source Publication | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
ISSN | 0168-9002 |
EISSN | 1872-9576 |
Volume | 893Pages:43-56 |
Subtype | Article |
Abstract | The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m(2). Silicon planes are interleaved with three layers of tungsten plates, resulting in about one radiation length of material in the tracker. Internal alignment parameters of the tracker have been determined on orbit, with non-showering protons and helium nuclei. We describe the alignment procedure and present the position resolution and alignment stability measurements. |
Keyword | Cosmic-ray detectors Gamma-ray telescopes Alignment Silicon-strip detectors |
DOI | 10.1016/j.nima.2018.02.105 |
Indexed By | SCI ; EI |
Correlation | 强相关 |
Research Direction | 综述 |
Member Type | 非核心团队 |
Language | 英语 |
WOS Research Area | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics |
WOS Subject | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Nuclear ; Physics, Particles & Fields |
WOS ID | WOS:000430167800007 |
EI Accession Number | 20181204930299 |
ADS Bibcode | 2018NIMPA.893...43T |
AXRIV CODE | 1712 |
inspireid | 1641812 |
major scientific facilities | 硬X射线调制望远镜 |
Citation statistics |
Cited Times:17 [INSPIRE]
Cited Times:21 [ADS]
|
Document Type | 期刊论文 |
Identifier | http://ir.ihep.ac.cn/handle/311005/282248 |
Collection | 硬X射线调制望远镜卫星 实验物理中心 粒子天体物理中心 中国科学院高能物理研究所_中国散裂中子源 东莞研究部 管理与技术支持 |
Affiliation | 中国科学院高能物理研究所 |
First Author Affilication | Institute of High Energy |
Recommended Citation GB/T 7714 | Tykhonov, A,Ambrosi, G,Asf,et al. Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2018,893:43-56. |
APA | Tykhonov, A.,Ambrosi, G.,Asf.,iyarov, R.,Azzarello, P.,...&Zhao H.(2018).Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,893,43-56. |
MLA | Tykhonov, A,et al."Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 893(2018):43-56. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment