Sun SF(孙世峰); Zhang ZM(章志明); Shuai L(帅磊); Li DW(李道武); Wang YJ(王英杰); Liu YT(刘彦韬); Huang XC(黄先超); Tang HH(唐浩辉); Li T(李婷); Chai P(柴培); Zhang YW(张译文); Zhou W(周魏); Yang MJ(杨明洁); Wei CF(魏存峰); Ma CX(马创新); Wei L(魏龙); Sun, SF; Zhang, ZM; Shuai, L; Li, DW; Wang, YJ; Liu, YT; Huang, XC; Tang, HH; Li, T; Chai, P; Zhang, YW; Zhou, W; Yang, MJ; Wei, CF; Ma, CX; Wei, L
2016
Source PublicationAPPLIED RADIATION AND ISOTOPES
ISSN0969-8043
Volume107Pages:177-182
SubtypeArticle
AbstractThis paper presents a coded aperture method to remotely estimate the radioactivity of a source. The activity is estimated from the detected counts and the estimated source location, which is extracted by factoring the effect of aperture magnification. A 6 mm thick tungsten-copper alloy coded aperture mask is used to modulate the incoming gamma-rays. The location of point and line sources in all three dimensions was estimated with an accuracy of less than 10% when the source-camera distance was about 4 m. The estimated activities were 17.6% smaller and 50.4% larger than the actual activities for the point and line sources, respectively. (C) 2015 Elsevier Ltd. All rights reserved.
KeywordSource localization Source activity determination Coded aperture Far-filed measurements Gamma camera Modified Uniformly Redundant Array (MURA)
DOI10.1016/j.apradiso.2015.10.021
Indexed BySCI
Language英语
WOS IDWOS:000367410300029
Citation statistics
Document Type期刊论文
Identifierhttp://ir.ihep.ac.cn/handle/311005/247994
Collection核技术应用研究中心
Recommended Citation
GB/T 7714
Sun SF,Zhang ZM,Shuai L,et al. Far field 3D localization of radioactive hot spots using a coded aperture camera[J]. APPLIED RADIATION AND ISOTOPES,2016,107:177-182.
APA 孙世峰.,章志明.,帅磊.,李道武.,王英杰.,...&Wei, L.(2016).Far field 3D localization of radioactive hot spots using a coded aperture camera.APPLIED RADIATION AND ISOTOPES,107,177-182.
MLA 孙世峰,et al."Far field 3D localization of radioactive hot spots using a coded aperture camera".APPLIED RADIATION AND ISOTOPES 107(2016):177-182.
Files in This Item:
File Name/Size DocType Version Access License
149.pdf(1955KB)期刊论文作者接受稿限制开放CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[孙世峰]'s Articles
[章志明]'s Articles
[帅磊]'s Articles
Baidu academic
Similar articles in Baidu academic
[孙世峰]'s Articles
[章志明]'s Articles
[帅磊]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[孙世峰]'s Articles
[章志明]'s Articles
[帅磊]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.