Measurement of integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility | |
Yang, JM; Gan, XS; Zhao, Y; Cui, MQ; Zhu, T; Zhao, YD; Sun, LJ; Zheng, L; Yan, F![]() ![]() ![]() ![]() | |
2011 | |
发表期刊 | CHINESE PHYSICS B
![]() |
卷号 | 20期号:1页码:10705 |
通讯作者 | [Yang Jia-Min ; Gan Xin-Shi ; Zhao Yang ; Zhu Tuo ; Hu Zhi-Min ; Wei Min-Xi ; Zhang Ji-Yan ; Yi Rong-Qing] China Acad Engn Phys, Res Ctr Laser Fus, Mianyang 621900, Peoples R China ; [Cui Ming-Qi ; Zhao Yi-Dong ; Sun Li-Juan ; Zheng Lei ; Yan Fen] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China |
摘要 | Integral diffraction coefficients of the crystal are the essential data of a crystal spectrometer which is extensively used to measure quantitative x-ray spectra of high temperature plasmas in kilo-electron-volt region. An experimental method has been developed to measure the integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility. the integral diffraction coefficients of several crystals including polyethylene terephthalate (PET), thallium acid phthalate(TlAP) and rubidium acid phthalate(RAP) crystals have been measured in the x-ray energy range 2100-5600 eV and compared with the calculations of the 'Darwin Prins' and the 'Mosaic' models. It is shown that the integral diffraction coefficients of these crystals are between the calculations of the 'Darwin Prins' and the 'Mosaic' models, but more close to the 'Darwin Prins' model calculations. |
文章类型 | Article |
关键词 | integral dirraction coefficient crystal x-ray spectrum measurement high temperature plasmas |
学科领域 | Physics |
研究领域[WOS] | Physics |
DOI | 10.1088/1674-1056/20/1/010705 |
URL | 查看原文 |
语种 | 英语 |
WOS类目 | Physics, Multidisciplinary |
WOS记录号 | WOS:000286676000037 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ihep.ac.cn/handle/311005/240394 |
专题 | 多学科研究中心 加速器中心 |
作者单位 | 中国科学院高能物理研究所 |
推荐引用方式 GB/T 7714 | Yang, JM,Gan, XS,Zhao, Y,et al. Measurement of integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility[J]. CHINESE PHYSICS B,2011,20(1):10705. |
APA | Yang, JM.,Gan, XS.,Zhao, Y.,Cui, MQ.,Zhu, T.,...&鄢芬.(2011).Measurement of integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility.CHINESE PHYSICS B,20(1),10705. |
MLA | Yang, JM,et al."Measurement of integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility".CHINESE PHYSICS B 20.1(2011):10705. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
8455.pdf(1170KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论