IHEP OpenIR  > 粒子天体物理中心
Application of Direct Demodulation Technique in Analysis of Ground Verification Test of X-Ray Spectrometer for Chang'E Mission
Zhang JY(张家宇); Wang HY(王焕玉); Zhang CM(张承模); Liang XH(梁晓华); Yang JW(杨家卫); Wang JZ(汪锦州); Cao XL(曹学蕾); Gao M(高旻); Cui XZ(崔兴柱); Peng WX(彭文溪); Zhang, JY; Wang, HY; Zhang, CM; Liang, XH; Yang, JW; Wang, JZ; Cao, XL; Gao, M; Cui, XZ; Peng, WX
2008
Source PublicationSPECTROSCOPY AND SPECTRAL ANALYSIS
Volume28Issue:10Pages:2450-2454
Corresponding Author[Zhang Jia-yu ; Wang Huan-yu ; Zhang Cheng-mo ; Liang Xiao-hua ; Yang Jia-wei ; Wang Jin-zhou ; Cao Xue-lei ; Gao Min ; Cui Xing-zhu ; Peng Wen-xi] Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophys, Beijing 100049, Peoples R China
SubtypeArticle
AbstractAn X-ray fluorescence imaging spectrometer based on silicon PIN photodiodes was designed and constructed for the Chang'E mission,. the first lunar spacecraft, and will be in operation at a 200 km circular lunar orbit with one year lifetime. The X-ray fluorescence spectrometer consists of two silicon PIN photodiodes modules, each holds two low energy detector units to analyze the distribution of useful elements and to estimate the abundance on the moon, which is one of the objectives of the X-ray fluorescence spectrometer experiment. The low energy detector unit is 25 mm(2), 500 mu m thick, with the energy band of 1-10 keV, and energy resolution of: similar to 5% at S. 9 keV. The ground verification tests of the X-ray spectrometer for Chang'E mission were introduced in the present paper. Taking the energy response matrix of the spectrometer as the foundation and using the direct demodulation technique and fundamental parameter method, the authors performed some quantitative and qualitative analysis of these scientific data which came from the ground verification tests, especially for Mg, Al and Si elements.
KeywordX-ray spectrometer Verification test Quantitative analysis
Subject AreaSpectroscopy
DOI10.3964/j.issn.1000-0593(2008)10-2450-05
URL查看原文
Language英语
WOS Research AreaSpectroscopy
WOS SubjectSpectroscopy
WOS IDWOS:000260697000055
Citation statistics
Document Type期刊论文
Identifierhttp://ir.ihep.ac.cn/handle/311005/239755
Collection粒子天体物理中心
Affiliation中国科学院高能物理研究所
First Author AffilicationInstitute of High Energy
Recommended Citation
GB/T 7714
Zhang JY,Wang HY,Zhang CM,et al. Application of Direct Demodulation Technique in Analysis of Ground Verification Test of X-Ray Spectrometer for Chang'E Mission[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2008,28(10):2450-2454.
APA 张家宇.,王焕玉.,张承模.,梁晓华.,杨家卫.,...&Peng, WX.(2008).Application of Direct Demodulation Technique in Analysis of Ground Verification Test of X-Ray Spectrometer for Chang'E Mission.SPECTROSCOPY AND SPECTRAL ANALYSIS,28(10),2450-2454.
MLA 张家宇,et al."Application of Direct Demodulation Technique in Analysis of Ground Verification Test of X-Ray Spectrometer for Chang'E Mission".SPECTROSCOPY AND SPECTRAL ANALYSIS 28.10(2008):2450-2454.
Files in This Item:
File Name/Size DocType Version Access License
7108.pdf(303KB)期刊论文作者接受稿限制开放CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[张家宇]'s Articles
[王焕玉]'s Articles
[张承模]'s Articles
Baidu academic
Similar articles in Baidu academic
[张家宇]'s Articles
[王焕玉]'s Articles
[张承模]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[张家宇]'s Articles
[王焕玉]'s Articles
[张承模]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.