Diffraction-Enhanced Radiography of Various Mouse Organs
Zhang, X; Yang, XR; Chen, Y; Li, HQ; Liu, WY; Yuan, QX; Chen, SL; Yuan QX(袁清习)
刊名AMERICAN JOURNAL OF ROENTGENOLOGY
2010
卷号195期号:3页码:545-549
关键词bile ducts blood vessels diffraction-enhanced imaging synchrotron radiation
学科分类Radiology, Nuclear Medicine & Medical Imaging
DOI10.2214/AJR.09.4090
通讯作者[Chen, Shao-Liang] Fudan Univ, Affiliated ZhongShan Hosp, Dept Nucl Med, Shanghai 200032, Peoples R China ; [Liu, Wen-Ya] Xinjiang Med Univ, Affiliated Hosp 1, Dept Radiol, Urumqi, Peoples R China ; [Li, Hai-Qing] Shanghai Jiao Tong Univ, Sch Med, Rui Jin Hosp, Shanghai 200030, Peoples R China ; [Chen, Yu ; Yuan, Qing-Xi] Chinese Acad Sci, Inst High Energy Phys, Beijing, Peoples R China ; [Yang, Xin-Rong] Fudan Univ, ZhongShan Hosp, Liver Canc Inst, Shanghai 200032, Peoples R China ; [Zhang, Xi] Fudan Univ, Shanghai Med Coll, Dept Oncol, Shanghai 200032, Peoples R China ; [Zhang, Xi] Fudan Univ, Affiliated Canc Hosp, Dept Radiol, Shanghai 200032, Peoples R China
文章类型Article
英文摘要OBJECTIVE. The purposes of this study were to evaluate whether a novel radiographic technique, diffraction-enhanced radiographic imaging, would render high-contrast images of mouse livers, hearts, and kidneys and to determine whether blood vessels and bile ducts can be differentiated on images of mouse livers. MATERIALS AND METHODS. For imaging of the bile ducts, mouse livers were excised 20 or 35 days after ligation of the common bile duct. Livers, hearts, and kidneys of control mice also were excised for imaging. The diffraction-enhanced imaging experiments were performed with a silicon 333 crystal diffraction plane and an 18-keV x-ray beam. The beam incident to the sample measured 20 mm (horizontal) x 11 mm (vertical). Images were acquired with the analyzer crystal set at different positions of the rocking curve. RESULTS. Only dilated bile ducts, no normal bile ducts, were found. With diffraction-enhanced imaging without a contrast agent, the blood vessels of the liver, heart, and kidney were visualized to a scale of tens of micrometers. CONCLUSION. Diffraction-enhanced imaging with a silicon 333 crystal plane had excellent contrast in the detection of blood vessels and pathologically dilated bile ducts and may be a promising radiographic technique for basic medical research.
类目[WOS]Radiology, Nuclear Medicine & Medical Imaging
研究领域[WOS]Radiology, Nuclear Medicine & Medical Imaging
原文出处查看原文
语种英语
WOS记录号WOS:000281180500002
引用统计
被引频次:5[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/237899
专题中国科学院高能物理研究所_多学科研究中心_期刊论文
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Zhang, X,Yang, XR,Chen, Y,et al. Diffraction-Enhanced Radiography of Various Mouse Organs[J]. AMERICAN JOURNAL OF ROENTGENOLOGY,2010,195(3):545-549.
APA Zhang, X.,Yang, XR.,Chen, Y.,Li, HQ.,Liu, WY.,...&袁清习.(2010).Diffraction-Enhanced Radiography of Various Mouse Organs.AMERICAN JOURNAL OF ROENTGENOLOGY,195(3),545-549.
MLA Zhang, X,et al."Diffraction-Enhanced Radiography of Various Mouse Organs".AMERICAN JOURNAL OF ROENTGENOLOGY 195.3(2010):545-549.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
4587.pdf(825KB) 开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, X]的文章
[Yang, XR]的文章
[Chen, Y]的文章
百度学术
百度学术中相似的文章
[Zhang, X]的文章
[Yang, XR]的文章
[Chen, Y]的文章
必应学术
必应学术中相似的文章
[Zhang, X]的文章
[Yang, XR]的文章
[Chen, Y]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 4587.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。