RESULTS ON THE CALIBRATION OF THE L3 BGO CALORIMETER WITH COSMIC-RAYS
BAKKEN, JA; BARONE, L; BAY, A; BLAISING, JJ; BORGIA, B; BOURILKOV, D; BOUTIGNY, D; BROCK, IC; BUISSON, C; CAPELL, M; CHATURVEDI, UK; CHEMARIN, M; CLARE, R; COIGNET, G; DENES, P; DENOTARISTEFANI, F; DIEMOZ, M; DUCHESNEAU, D; ELMAMOUNI, H; EXTERMANN, P; FAY, J; FERRONI, F; GAILLOUD, M; GOUJON, D; GRATTA, G; GUPTA, VK; HILGERS, K; ILLE, B; JANSSEN, H; KARYOTAKIS, Y; KASSER, A; KIENZLEFOCACCI, MN; KRENZ, W; LEBRUN, P; LECOQ, P; LEONARDI, E; LINDE, FL; LINDEMANN, B; LONGO, E; LU, YS; LUCI, C; LUCKEY, D; MARTIN, JP; MERK, M; MICKE, M; MORGANTI, S; NEWMAN, H; ORGANTINI, G; PIROUE, PA; READ, K; ROSIERLEES, S; ROSSELET, P; SAUVAGE, G; SCHMITZ, D; SCHNEEGANS, M; SCHWENKE, J; STICKLAND, DP; TULLY, C; VALENTE, E; VIVARGENT, M; VUILLEUMIER, L; WANG, YF; WEBER, A; WEILL, R; WENNINGER, J
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
1994
卷号343期号:2-3页码:456-462
学科分类Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy
通讯作者NIKHEF,1009 DB AMSTERDAM,NETHERLANDS ; IN2P3,LAPP,CNRS,F-74941 ANNECY LE VIEUX,FRANCE ; IHEP,100039 BEIJING,PEOPLES R CHINA ; INFN,SEZ BOLOGNA,I-40126 BOLOGNA,ITALY ; HUNGARIAN ACAD SCI,CENT RES INST,H-1525 BUDAPEST 114,HUNGARY ; CERN,EUROPEAN LAB PARTICLE PHYS,CH-1211 GENEVA 23,SWITZERLAND ; WORLD LAB,FBLJA PROJECT,CH-1211 GENEVA 23,SWITZERLAND ; UNIV GENEVA,CH-1211 GENEVA 4,SWITZERLAND ; LAWRENCE LIVERMORE NATL LAB,LIVERMORE,CA 94550 ; UNIV LYON 1,INST PHYS NUCL LYON,IN2P3,CNRS,F-69622 VILLEURBANNE,FRANCE ; MOSCOW THEORET & EXPTL PHYS INST,MOSCOW,RUSSIA ; OAK RIDGE NATL LAB,OAK RIDGE,TN 37831 ; CATHOLIC UNIV NIJMEGEN,6525 ED NIJMEGEN,NETHERLANDS ; INFN,SEZ ROMA,I-00185 ROME,ITALY ; CARNEGIE MELLON UNIV,PITTSBURGH,PA 15213 ; MIT,CAMBRIDGE,MA 02139 ; UNIV LAUSANNE,CH-1015 LAUSANNE,SWITZERLAND ; CALTECH,PASADENA,CA 91125 ; PRINCETON UNIV,PRINCETON,NJ 08544 ; UNIV ROMA LA SAPIENZA,I-00185 ROME,ITALY
文章类型Article
英文摘要During 1991 two cosmic rays runs took place for the calibration of the L3 electromagnetic calorimeter. In this paper we present the results of the first high statistics cosmic ray calibration of the calorimeter in situ, including the end caps. Results show that the accuracy on the measurement of the calibration constants that can be achieved in one month of data taking is of 1.3%.
类目[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy
研究领域[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics ; Spectroscopy
原文出处查看原文
语种英语
WOS记录号WOS:A1994NG65400018
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/237560
专题中国科学院高能物理研究所_粒子天体物理中心_期刊论文
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
BAKKEN, JA,BARONE, L,BAY, A,et al. RESULTS ON THE CALIBRATION OF THE L3 BGO CALORIMETER WITH COSMIC-RAYS[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,1994,343(2-3):456-462.
APA BAKKEN, JA.,BARONE, L.,BAY, A.,BLAISING, JJ.,BORGIA, B.,...&WENNINGER, J.(1994).RESULTS ON THE CALIBRATION OF THE L3 BGO CALORIMETER WITH COSMIC-RAYS.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,343(2-3),456-462.
MLA BAKKEN, JA,et al."RESULTS ON THE CALIBRATION OF THE L3 BGO CALORIMETER WITH COSMIC-RAYS".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 343.2-3(1994):456-462.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
4135.pdf(518KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[BAKKEN, JA]的文章
[BARONE, L]的文章
[BAY, A]的文章
百度学术
百度学术中相似的文章
[BAKKEN, JA]的文章
[BARONE, L]的文章
[BAY, A]的文章
必应学术
必应学术中相似的文章
[BAKKEN, JA]的文章
[BARONE, L]的文章
[BAY, A]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 4135.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。