Knowledge Management System Of Institute of High Energy
Attenuation correction with region growing method used in the positron emission mammography imaging system | |
Gu XY(顾笑悦)![]() ![]() ![]() ![]() ![]() ![]() ![]() | |
2015 | |
Source Publication | CHINESE PHYSICS C
![]() |
ISSN | 1674-1137 |
Volume | 39Issue:10Pages:108202 |
Corresponding Author | 顾笑悦 |
Subtype | Article |
Abstract | The Positron Emission Mammography imaging system (PEMi) provides a novel nuclear diagnosis method dedicated for breast imaging. With a better resolution than whole body PET, PEMi can detect millimeter-sized breast tumors. To address the requirement of semi-quantitative analysis with a radiotracer concentration map of the breast, a new attenuation correction method based on a three-dimensional seeded region growing image segmentation (3DSRG-AC) method has been developed. The method gives a 3D connected region as the segmentation result instead of image slices. The continuity property of the segmentation result makes this new method free of activity variation of breast tissues. The threshold value chosen is the key process for the segmentation method. The first valley in the grey level histogram of the reconstruction image is set as the lower threshold, which works well in clinical application. Results show that attenuation correction for PEMi improves the image quality and the quantitative accuracy of radioactivity distribution determination. Attenuation correction also improves the probability of detecting small and early breast tumors. |
Keyword | breast PET attenuation correction region growing image segmentation |
Subject Area | Physics |
DOI | 10.1088/1674-1137/39/10/108202 |
Indexed By | SCI ; ADS |
Language | 英语 |
WOS Research Area | Physics, Nuclear ; Physics, Particles & Fields |
WOS Subject | Physics |
WOS ID | WOS:000365149700022 |
ADS Bibcode | 2015ChPhC..39j8202G |
ADS URL | https://ui.adsabs.harvard.edu/abs/2015ChPhC..39j8202G |
ADS CITATIONS | https://ui.adsabs.harvard.edu/abs/2015ChPhC..39j8202G/citations |
Citation statistics |
Cited Times:1 [ADS]
|
Document Type | 期刊论文 |
Identifier | http://ir.ihep.ac.cn/handle/311005/228966 |
Collection | 核技术应用研究中心 中国科学院高能物理研究所_中国散裂中子源 |
Recommended Citation GB/T 7714 | Gu XY,Li L,Yin PF,et al. Attenuation correction with region growing method used in the positron emission mammography imaging system[J]. CHINESE PHYSICS C,2015,39(10):108202. |
APA | 顾笑悦.,李琳.,尹鹏飞.,贠明凯.,柴培.,...&W. Long.(2015).Attenuation correction with region growing method used in the positron emission mammography imaging system.CHINESE PHYSICS C,39(10),108202. |
MLA | 顾笑悦,et al."Attenuation correction with region growing method used in the positron emission mammography imaging system".CHINESE PHYSICS C 39.10(2015):108202. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment