Characteristics of Friedel pairs and diffraction contrast tomography with non-perpendicular rotation axis
Yi QR(易栖如); Li G(黎刚); 张杰(多); Gao ZH(高振华); Wang YP(王艳萍); Yi, QR; Li, G; Zhang, J; Luo, SN; Fan, D; Gao, ZH; Wang, YP; Gao, GF; Jiang, SP; Jiang, XM
刊名JOURNAL OF SYNCHROTRON RADIATION
2015
卷号22页码:1062-1071
关键词diffraction contrast tomography Friedel pair non-perpendicular rotation axis non-perpendicularity
学科分类Instruments & Instrumentation; Optics; Physics
DOI10.1107/S1600577515006165
通讯作者黎刚
文章类型Article
英文摘要The characteristics of Friedel pairs in diffraction contrast tomography (DCT) are studied in the condition that the rotation axis of the sample is not exactly perpendicular to the incident X-ray direction. For the rotation axis approximately aligned along the vertical direction, the Friedel pairs close to the horizontal plane are insensitive to the non-perpendicularity of the rotation axis, and can be used to refine the sample-to-detector distance and X-ray energy, while the Friedel pairs close to the vertical direction are sensitive to the non-perpendicularity of the rotation axis, and can be used to determine the rotation axis orientation. The correct matching proportion of Friedel pairs decreases with increasing non-perpendicularity of the rotation axis. A method of data processing considering rotation axis misalignment is proposed, which significantly increases the correct matching and indexing proportions of the diffraction spots. A pure aluminium polycrystalline sample is investigated using DCT at beamline 4W1A of Beijing Synchrotron Radiation Facility. Based on the analysis of Friedel pairs, the sample-to-detector distance and X-ray energy are refined to be 8.67 mm and 20.04 keV, respectively. The non-perpendicular angle of the rotation axis is calculated to be 0.10 degrees. With these refined geometric parameters, the matching proportion of the spatial position of diffraction spots is 90.62%. Three-dimensional reconstruction of the sample with 13 grains is realised using the algebraic reconstruction technique. It is demonstrated that the precise correction of the orientation of the sample rotation axis is effective in DCT suffering from rotation axis misalignment, and the higher accuracy in determining the rotation axis is expected to improve the reconstruction precision of grains.
类目[WOS]Instruments & Instrumentation ; Optics ; Physics, Applied
收录类别SCI ; EI ; CA
WOS记录号WOS:000357407900024
引用统计
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/228620
专题中国科学院高能物理研究所_多学科研究中心_期刊论文
中国科学院高能物理研究所_多学科研究中心
推荐引用方式
GB/T 7714
Yi QR,Li G,Zhang J,et al. Characteristics of Friedel pairs and diffraction contrast tomography with non-perpendicular rotation axis[J]. JOURNAL OF SYNCHROTRON RADIATION,2015,22:1062-1071.
APA 易栖如.,黎刚.,张杰.,高振华.,王艳萍.,...&Jiang, XM.(2015).Characteristics of Friedel pairs and diffraction contrast tomography with non-perpendicular rotation axis.JOURNAL OF SYNCHROTRON RADIATION,22,1062-1071.
MLA 易栖如,et al."Characteristics of Friedel pairs and diffraction contrast tomography with non-perpendicular rotation axis".JOURNAL OF SYNCHROTRON RADIATION 22(2015):1062-1071.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
565.pdf(1167KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[易栖如]的文章
[黎刚]的文章
[张杰(多)]的文章
百度学术
百度学术中相似的文章
[易栖如]的文章
[黎刚]的文章
[张杰(多)]的文章
必应学术
必应学术中相似的文章
[易栖如]的文章
[黎刚]的文章
[张杰(多)]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 565.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。