IHEP OpenIR
Experimental research on the feature of an x-ray Talbot-Lau interferometer versus tube accelerating voltage
Wang, SH; Olbinado, MP; Momose, A; Han, HJ; Hu, RF; Wang, ZL; Gao, K; Zhang, K; Zhu, PP; Wu, ZY; Zhang K(张凯); Zhu PP(朱佩平); Wu ZY(吴自玉)
2015
Source PublicationCHINESE PHYSICS B
ISSN1674-1056
EISSN1741-4199
Volume24Issue:6Pages:68703
Corresponding Author吴自玉
SubtypeArticle
AbstractX-ray Talbot-Lau interferometer has been used most widely to perform x-ray phase-contrast imaging with a conventional low-brilliance x-ray source, and it yields high-sensitivity phase and dark-field images of samples producing low absorption contrast, thus bearing tremendous potential for future clinical diagnosis. In this work, by changing the accelerating voltage of the x-ray tube from 35 kV to 45 kV, x-ray phase-contrast imaging of a test sample is performed at each integer value of the accelerating voltage to investigate the characteristic of an x-ray Talbot-Lau interferometer (located in the Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Japan) versus tube voltage. Experimental results and data analysis show that within a range this x-ray Talbot-Lau interferometer is not sensitive to the accelerating voltage of the tube with a constant fringe visibility of similar to 44%. This x-ray Talbot-Lau interferometer research demonstrates the feasibility of a new dual energy phase-contrast x-ray imaging strategy and the possibility to collect a refraction spectrum.
Keywordx-ray Talbot-Lau interferometer x-ray imaging phase-contrast tube accelerating voltage x-ray tube
Subject AreaPhysics
DOI10.1088/1674-1056/24/6/068703
Indexed BySCI ; ADS ; EI
Language英语
WOS Research AreaPhysics, Multidisciplinary
WOS SubjectPhysics
WOS IDWOS:000358130200104
ADS Bibcode2015ChPhB..24f8703W
ADS URLhttps://ui.adsabs.harvard.edu/abs/2015ChPhB..24f8703W
ADS CITATIONShttps://ui.adsabs.harvard.edu/abs/2015ChPhB..24f8703W/citations
Citation statistics
Cited Times:5 [ADS]
Document Type期刊论文
Identifierhttp://ir.ihep.ac.cn/handle/311005/228600
Collection中国科学院高能物理研究所
Recommended Citation
GB/T 7714
Wang, SH,Olbinado, MP,Momose, A,et al. Experimental research on the feature of an x-ray Talbot-Lau interferometer versus tube accelerating voltage[J]. CHINESE PHYSICS B,2015,24(6):68703.
APA Wang, SH.,Olbinado, MP.,Momose, A.,Han, HJ.,Hu, RF.,...&吴自玉.(2015).Experimental research on the feature of an x-ray Talbot-Lau interferometer versus tube accelerating voltage.CHINESE PHYSICS B,24(6),68703.
MLA Wang, SH,et al."Experimental research on the feature of an x-ray Talbot-Lau interferometer versus tube accelerating voltage".CHINESE PHYSICS B 24.6(2015):68703.
Files in This Item:
File Name/Size DocType Version Access License
544.pdf(1009KB)期刊论文作者接受稿开放获取CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Wang, SH]'s Articles
[Olbinado, MP]'s Articles
[Momose, A]'s Articles
Baidu academic
Similar articles in Baidu academic
[Wang, SH]'s Articles
[Olbinado, MP]'s Articles
[Momose, A]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Wang, SH]'s Articles
[Olbinado, MP]'s Articles
[Momose, A]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.