IHEP OpenIR  > 实验物理中心
Modified method for diffraction aberration of one-dimensional wire chamber
Alternative Title一维丝室气体探测器衍射像差的修正方法研究
Wen ZW(温志文); Qi HR(祁辉荣); Dai HL(代洪亮); Zhang YL(张余炼); Wei K(魏堃); Zhang J(张建); Ou YQ(欧阳群); Wen, ZW; Qi, HR; Dai, HL; Zhang, YL; Wei, K; Zhang, J; Ouyang, Q; Shao, JX
2015
Source Publication物理学报
ISSN1000-3290
Volume64Issue:8Pages:82901
Corresponding Author祁辉荣
SubtypeArticle
AbstractThe one-dimensional position sensitive wire gaseous detector is developed for the synchrotron radiation diffraction, which consists of a single wire of gold-plated tungsten and 200 cathode strips as the readout. The induced signal is produced by the several adjacent cathode strips when X-ray is incident on anode wire with high voltage. Using the center gravity method to analyze the adjacent signals in one dimension, the primary ionization position of the X-ray can be obtained and the position resolution is 160 mu m (FWHM). In Beijing Synchrotron Radiation Facility, the diffraction test is done at the experimental station. When the X-ray irradiates the crystal sample of SiO2, the different sizes of the diffraction rings can be produced. The diffraction angles are measured to be 11.148. and 14.201., and the two-dimensional diffraction rings are reconstructed when the detector is moved and scanned with the several steps in the diffraction ring range. The diffraction aberration of one-dimensional wire chamber is very obvious. In the paper, the relevant influence factors of the detector construct are discussed. The thickness of the working gas and the width of active area window can give rise to the diffraction ring aberration. The theoretical calculation value of the diffraction aberration is larger than the position resolution value of the gaseous detector. The correction method is established based on the corresponding physical analysis, and by this method the value of the diffraction ring point is calculated. The relative aberration of diffraction position is improved by up to 7% with using the method, and the two-dimensional diffraction ring with no aberration can be reconstructed.
Keywordgas detector diffraction measurements synchrotron radiation correction method
Subject AreaPhysics
DOI10.7498/aps.64.082901
Indexed BySCI ; EI
Language中文
WOS Research AreaPhysics, Multidisciplinary
WOS SubjectPhysics
WOS IDWOS:000354059200013
Citation statistics
Document Type期刊论文
Identifierhttp://ir.ihep.ac.cn/handle/311005/228551
Collection实验物理中心
Recommended Citation
GB/T 7714
Wen ZW,Qi HR,Dai HL,et al. Modified method for diffraction aberration of one-dimensional wire chamber[J]. 物理学报,2015,64(8):82901.
APA 温志文.,祁辉荣.,代洪亮.,张余炼.,魏堃.,...&Shao, JX.(2015).Modified method for diffraction aberration of one-dimensional wire chamber.物理学报,64(8),82901.
MLA 温志文,et al."Modified method for diffraction aberration of one-dimensional wire chamber".物理学报 64.8(2015):82901.
Files in This Item:
File Name/Size DocType Version Access License
488.pdf(692KB)期刊论文作者接受稿限制开放CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[温志文]'s Articles
[祁辉荣]'s Articles
[代洪亮]'s Articles
Baidu academic
Similar articles in Baidu academic
[温志文]'s Articles
[祁辉荣]'s Articles
[代洪亮]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[温志文]'s Articles
[祁辉荣]'s Articles
[代洪亮]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.