Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation
Singh, VP; Medhat, ME; Badiger, NM
刊名RADIATION PHYSICS AND CHEMISTRY
2015
卷号106页码:83-87
关键词Geant4 Mass energy-absorption coefficients Kerma Nuclear track detectors Buildup factor
学科分类Chemistry; Nuclear Science & Technology; Physics
DOI10.1016/j.radphyschem.2014.07.001
文章类型Article
英文摘要Geant4 Monte Carlo code simulations were used to solve experimental and theoretical complications for calculation of mass energy-absorption coefficients of elements, air, and compounds. The mass energy-absorption coefficients for nuclear track detectors were computed first time using Geant4 Monte Carlo code for energy 1 keV-20 MeV. Very good agreements for simulated results of mass energy-absorption coefficients for carbon, nitrogen, silicon, sodium iodide and nuclear track detectors were observed on comparison with the values reported in the literatures. Kerma relative to air for energy 1 keV-20 MeV and energy absorption buildup factors for energy 50 keV-10 MeV up to 10 mfp penetration depths of the selected nuclear track detectors were also calculated to evaluate the absorption of the gamma photons. Geant4 simulation can be utilized for estimation of mass energy-absorption coefficients in elements and composite materials. (C) 2014 Elsevier Ltd. All rights reserved.
类目[WOS]Chemistry, Physical ; Nuclear Science & Technology ; Physics, Atomic, Molecular & Chemical
收录类别SCI ; EI
WOS记录号WOS:000344422400015
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/228211
专题中国科学院高能物理研究所_实验物理中心_期刊论文
推荐引用方式
GB/T 7714
Singh, VP,Medhat, ME,Badiger, NM. Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation[J]. RADIATION PHYSICS AND CHEMISTRY,2015,106:83-87.
APA Singh, VP,Medhat, ME,&Badiger, NM.(2015).Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation.RADIATION PHYSICS AND CHEMISTRY,106,83-87.
MLA Singh, VP,et al."Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation".RADIATION PHYSICS AND CHEMISTRY 106(2015):83-87.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
143.pdf(383KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Singh, VP]的文章
[Medhat, ME]的文章
[Badiger, NM]的文章
百度学术
百度学术中相似的文章
[Singh, VP]的文章
[Medhat, ME]的文章
[Badiger, NM]的文章
必应学术
必应学术中相似的文章
[Singh, VP]的文章
[Medhat, ME]的文章
[Badiger, NM]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 143.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。