Calibration and performances of the KLOE calorimeter
KLOE Collaboration
2009
发表期刊NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
卷号598期号:1页码:#REF!
通讯作者Di Micco, B (reprint author), Ist Nazl Fis Nucl, Sez Roma Tre, Rome, Italy.
摘要The KLOE experiment uses a fine sampling lead-scintillating fibre calorimeter to measure energy, time and position of neutral and charged particles. The overall detector consists of 88 modules organised in a barrel and two end-caps, for a total granularity of 2440 cells, read-out by photo-multipliers at both fibre ends. The chosen design of a high sampling fraction with the usage of thin lead layers and fast scintillating fibres allows to reach good efficiency for photon energies down to few MeV, good energy resolution and excellent time resolution. The design, calibration and performances of the calorimeter on efficiency, time/position/energy resolution and particle identification is reviewed. The overall calorimeter impact on kaon tagging and on physics results is also presented. (c) 2008 Elsevier B.V. All rights reserved.
文章类型Article
关键词Calorimeter Scintillating fibres High energy physics Timing
学科领域Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy
DOI10.1016/j.nima.2008.08.097
收录类别SCI
WOS类目Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy
WOS记录号WOS:000262662500058
引用统计
被引频次:8[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/227128
专题实验物理中心
推荐引用方式
GB/T 7714
KLOE Collaboration. Calibration and performances of the KLOE calorimeter[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2009,598(1):#REF!.
APA KLOE Collaboration.(2009).Calibration and performances of the KLOE calorimeter.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,598(1),#REF!.
MLA KLOE Collaboration."Calibration and performances of the KLOE calorimeter".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 598.1(2009):#REF!.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
2504.pdf(445KB)期刊论文作者接受稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[KLOE Collaboration]的文章
百度学术
百度学术中相似的文章
[KLOE Collaboration]的文章
必应学术
必应学术中相似的文章
[KLOE Collaboration]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。