X-ray polarization measurement of the Beamline 4B7 of Beijing synchrotron radiation facility using a PET crystal
Yang, JM; Gan, XS; Cui MQ(崔明启); Zhao YD(赵屹东); Sun LJ(孙立娟); Zheng L(郑雷); Yan F(鄢芬); Cui, MQ; Zhao, Y; Zhu, T; Zhao, YD; Sun, LJ; Zheng, L; Yan, F; Hu, ZM; Wei, MX; Zhang, JY; Yi, RQ
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
2010
卷号615期号:1页码:#REF!
关键词X-ray polarization Synchrotron radiation Crystal
学科分类Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy
DOI10.1016/j.nima.2009.12.076
通讯作者Yang, JM (reprint author), China Acad Engn Phys, Res Ctr Leaser Fus, POB 919-986, Mianyang 621900, Peoples R China.
文章类型Article
英文摘要An experimental method has been developed to measure the X-ray polarization of the Beamline 4B7 on Beijing Synchrotron Radiation Facility in the X-ray energy range 2100-5600 eV by using a PET crystal diagnostic system and rotating the system around the incident X-ray beam by 90 degrees. The experimental results show that the measured X-ray polarization is more than 0.88 in the photon energy range 2100-3600 eV with maximum of 0.99 at 2707.3 eV, and quickly decreases to about 0.38 at 4719.2 eV with photon energy increasing from 3600 to 4719.2 eV, then it keeps almost constant as the photon energy increases further to 5600 eV. (C) 2010 Elsevier B.V. All rights reserved.
类目[WOS]Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy
收录类别SCI
WOS记录号WOS:000276148800016
引用统计
被引频次:2[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/226141
专题中国科学院高能物理研究所_多学科研究中心_期刊论文
中国科学院高能物理研究所_多学科研究中心
推荐引用方式
GB/T 7714
Yang, JM,Gan, XS,Cui MQ,et al. X-ray polarization measurement of the Beamline 4B7 of Beijing synchrotron radiation facility using a PET crystal[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2010,615(1):#REF!.
APA Yang, JM.,Gan, XS.,崔明启.,赵屹东.,孙立娟.,...&Yi, RQ.(2010).X-ray polarization measurement of the Beamline 4B7 of Beijing synchrotron radiation facility using a PET crystal.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,615(1),#REF!.
MLA Yang, JM,et al."X-ray polarization measurement of the Beamline 4B7 of Beijing synchrotron radiation facility using a PET crystal".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 615.1(2010):#REF!.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
1154.pdf(227KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yang, JM]的文章
[Gan, XS]的文章
[崔明启]的文章
百度学术
百度学术中相似的文章
[Yang, JM]的文章
[Gan, XS]的文章
[崔明启]的文章
必应学术
必应学术中相似的文章
[Yang, JM]的文章
[Gan, XS]的文章
[崔明启]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 1154.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。