摘要In designing large-sized volume type phased array coils for human head imaging at ultrahigh fields, e.g., 7T, minimizing electromagnetic coupling among array elements is technically challenging. A new decoupling method based on induced current compensation or elimination (ICE) for a microstrip line planar array has recently been proposed. In this study, an eight-channel transmit/receive volume array with ICE-decoupled loop elements was built and investigated to demonstrate its feasibility and robustness for human head imaging at 7T. Isolation between adjacent loop elements was better than - 25 dB with a human head load. The worst-case of the isolation between all of the elements was about - 17.5 dB. All of the MRI experiments were performed on a 7T whole-body human MR scanner. Images of the phantom and human head were acquired and g-factor maps were measured and calculated to evaluate the performance of the coil array. Compared with the conventional capacitively decoupled array, the ICE-decoupled array demonstrated improved parallel imaging ability and had a higher SNR. The experimental results indicate that the transceiver array design with ICE decoupling technique might be a promising solution to designing high performance transmit/receive coil arrays for human head imaging at ultrahigh fields.
关键词Decoupling high field magnetic resonance imaging (MRI) human head induced current compensation or elimination (ICE) loop parallel imaging phased array radio-frequency (RF) coil
学科领域Computer Science; Engineering; Imaging Science & Photographic Technology; Radiology, Nuclear Medicine & Medical Imaging
DOI10.1109/TMI.2014.2313879
收录类别SCI
WOS记录号WOS:000341773600002
引用统计
被引频次:16[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/225026
专题核技术应用研究中心
推荐引用方式
GB/T 7714
Yan XQ,Yan, XQ,Feng BT,et al. 7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging[J]. IEEE TRANSACTIONS ON MEDICAL IMAGING,2014,33(9):1781-1787.
APA 燕新强.,Yan, XQ.,丰宝桐.,Zhang, XL.,Feng, BT.,...&魏龙.(2014).7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging.IEEE TRANSACTIONS ON MEDICAL IMAGING,33(9),1781-1787.
MLA 燕新强,et al."7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging".IEEE TRANSACTIONS ON MEDICAL IMAGING 33.9(2014):1781-1787.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
10966.pdf(2625KB)期刊论文作者接受稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[燕新强]的文章
[Yan, XQ]的文章
[丰宝桐]的文章
百度学术
百度学术中相似的文章
[燕新强]的文章
[Yan, XQ]的文章
[丰宝桐]的文章
必应学术
必应学术中相似的文章
[燕新强]的文章
[Yan, XQ]的文章
[丰宝桐]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。