IHEP OpenIR  > 多学科研究中心
Performance evaluation of CsI screens for X-ray imaging
Zhao BZ(赵博震); Qin XB(秦秀波); Feng ZD(冯召东); Zhao, BZ; Qin, XB; Feng, ZD; Wei, CF; Chen, Y; Wang, BY; Wei, L; Wei CF(魏存峰); Wang BY(王宝义); Wei L(魏龙)
2014
Source PublicationCHINESE PHYSICS C
ISSN1674-1137
EISSN2058-6132
Volume38Issue:11Pages:116003
AbstractCsI film has been one of the most extensively used scintillators for indirect X-ray imaging because of its needle-like micro-structure. The purpose of this paper is to investigate the imaging performance of CsI screen as a function of thickness and radiation quality. Four multilayer scintillation screens with microcolumnar CsI:Tl film (thicknesses of 50 mu m, 100 mu m, 200 mu m and 300 mu m) included were prepared and coupled to an optical imaging sensor. The modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) of these screens were evaluated based on the standard IEC 62220-1, and the results indicated that, in the medium spatial frequency range (1-6 lp/mm), the MTF of CsI screens with the same thickness was lower when the incident X-ray photon energy was higher, possibly owing to scattering and K-fluorescence re-absorption effects. The NNPS in the higher spatial frequency range (above 8 lp/mm) is dominated by stochastic noise while the entrance surface air Kerma (ESAK) decreases. For 100 mu m, 200 mu m and 300 mu m thick CsI screens, the DQE under RQA7 and RQA9 is lower than that under RQA3 and RQA5 due to low absorption efficiency.
Keywordmicrocolumnar CsI:Tl film scintillation screen DQE
Subject AreaPhysics
DOI10.1088/1674-1137/38/11/116003
Indexed BySCI
Language英语
WOS IDWOS:000344911400006
Citation statistics
Document Type期刊论文
Identifierhttp://ir.ihep.ac.cn/handle/311005/224954
Collection多学科研究中心
核技术应用研究中心
Recommended Citation
GB/T 7714
Zhao BZ,Qin XB,Feng ZD,et al. Performance evaluation of CsI screens for X-ray imaging[J]. CHINESE PHYSICS C,2014,38(11):116003.
APA 赵博震.,秦秀波.,冯召东.,Zhao, BZ.,Qin, XB.,...&魏龙.(2014).Performance evaluation of CsI screens for X-ray imaging.CHINESE PHYSICS C,38(11),116003.
MLA 赵博震,et al."Performance evaluation of CsI screens for X-ray imaging".CHINESE PHYSICS C 38.11(2014):116003.
Files in This Item:
File Name/Size DocType Version Access License
10855.pdf(453KB)期刊论文作者接受稿限制开放CC BY-NC-SAApplication Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[赵博震]'s Articles
[秦秀波]'s Articles
[冯召东]'s Articles
Baidu academic
Similar articles in Baidu academic
[赵博震]'s Articles
[秦秀波]'s Articles
[冯召东]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[赵博震]'s Articles
[秦秀波]'s Articles
[冯召东]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.