Measurements of charge transfer efficiency in a proton-irradiated swept charge device
Wang YS(王于仨); Yang YJ(杨彦佶); Chen Y(陈勇); Wang, YS; Yang, YJ; Chen, Y; Liu, XY; Cui, WW; Xu, YP; Li, CK; Li, MS; Han, DW; Chen, TX; Huo, J; Wang, J; Li, W; Hu, W; Zhang, Y; Lu, B; Yin, GH; Zhu, Y; Zhang, ZL; Liu XY(刘晓艳); Cui WW(崔苇苇); Xu YP(徐玉朋); Li CK(李承奎); Li MS(李茂顺); Han DW(韩大炜); Chen TX(陈田祥); Huo J(霍嘉); Wang J(王娟); Li W(李炜); Hu W(胡渭); Zhang Y(张艺); Lu B(陆波); Yin GH(尹国和); Zhu Y(朱玥); Zhang ZL(张子良)
刊名CHINESE PHYSICS C
2014
卷号38期号:6页码:66001
关键词CCD SCD HXMT LE CTE CTI proton-irradiated
学科分类Physics
DOI10.1088/1674-1137/38/6/066001
英文摘要Charged Coupled Devices (CCDs) have been successfully used in several low energy X-ray astronomical satellites over the past two decades. Their high energy resolution and high spatial resolution make them a perfect tool for low energy astronomy, such as observing the formation of galaxy clusters and the environment around black holes. The Low Energy X-ray Telescope (LE) group is developing a Swept Charge Device (SCD) for the Hard Xray Modulation Telescope (HXMT) satellite. A SCD is a special low energy X-ray CCD, which can be read out a thousand times faster than traditional CCDs, simultaneously keeping excellent energy resolution. A test method for measuring the charge transfer efficiency (CTE) of a prototype SCD has been set up. Studies of the charge transfer inefficiency (CTI) with a proton-irradiated SCD have been performed at a range of operating temperatures. The SCD is irradiated by 3x10(8)cm(-2) 10 MeV protons.
收录类别SCI
WOS记录号WOS:000337120100007
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/224925
专题中国科学院高能物理研究所_粒子天体物理中心_期刊论文
中国科学院高能物理研究所_粒子天体物理中心
推荐引用方式
GB/T 7714
Wang YS,Yang YJ,Chen Y,et al. Measurements of charge transfer efficiency in a proton-irradiated swept charge device[J]. CHINESE PHYSICS C,2014,38(6):66001.
APA 王于仨.,杨彦佶.,陈勇.,Wang, YS.,Yang, YJ.,...&张子良.(2014).Measurements of charge transfer efficiency in a proton-irradiated swept charge device.CHINESE PHYSICS C,38(6),66001.
MLA 王于仨,et al."Measurements of charge transfer efficiency in a proton-irradiated swept charge device".CHINESE PHYSICS C 38.6(2014):66001.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
10825.pdf(504KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[王于仨]的文章
[杨彦佶]的文章
[陈勇]的文章
百度学术
百度学术中相似的文章
[王于仨]的文章
[杨彦佶]的文章
[陈勇]的文章
必应学术
必应学术中相似的文章
[王于仨]的文章
[杨彦佶]的文章
[陈勇]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 10825.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。