Horizontal test for BEPC II 500 MHz spare cavity | |
Mi ZH(米正辉)![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | |
2012 | |
Source Publication | CHINESE PHYSICS C
![]() |
Volume | 36Issue:10Pages:996-999 |
Abstract | The horizontal test for the BEPC II 500 MHz spare cavity has been completed at IHEP. The maximum voltage of the cavity reached 2.17 MV, while Q(0) was 5.78x10(8). The process and results of the high power horizontal test are presented and discussed in this paper. |
Keyword | horizontal test spare cavity 500 MHz cavity |
Subject Area | Physics |
DOI | 10.1088/1674-1137/36/10/014 |
Indexed By | SCI ; INSPIREHEP |
WOS ID | WOS:000309900800014 |
inspireid | 1202550 |
inspireURL | https://inspirehep.net/literature/1202550 |
Citation statistics |
Cited Times:0 [INSPIRE]
|
Document Type | 期刊论文 |
Identifier | http://ir.ihep.ac.cn/handle/311005/224091 |
Collection | 加速器中心 |
Recommended Citation GB/T 7714 | Mi ZH,Sun Y,Wang GW,et al. Horizontal test for BEPC II 500 MHz spare cavity[J]. CHINESE PHYSICS C,2012,36(10):996-999. |
APA | 米正辉.,孙毅.,王光伟.,Mi, ZH.,Sun, Y.,...&张娟.(2012).Horizontal test for BEPC II 500 MHz spare cavity.CHINESE PHYSICS C,36(10),996-999. |
MLA | 米正辉,et al."Horizontal test for BEPC II 500 MHz spare cavity".CHINESE PHYSICS C 36.10(2012):996-999. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment