IHEP OpenIR  > 实验物理中心
Study of the THGEM detector with a reflective CsI photocathode
Liu HB(刘宏邦); Zheng YH(郑阳恒); Xie YG(谢一冈); Lv JG(吕军光); Zhou L(周莉); Yu BX(俞伯祥); Zhang AW(章爱武); An ZH(安正华); Xie YG(谢宇广); Zhang D(张东); Zheng ZP(郑志鹏)
2011
发表期刊中国物理C
期号4页码:363-367
摘要The THGEM detector without and with a CsI has been tested successfully. The optimal parameters of THGEM have been determined from eight samples. The UV photoelectric effect of the CsI photocathode is observed. The changing tendency related to the extraction efficiency (εextr) versus the extraction e...
关键词THGEM CsI photocathode UV
项目资助者Supported by National Natural Science Foundation of China (10775181,10775151) ; A. Breskin of Weizmann Inst., P. Picchi and A.Braem of CERN for their friendly discussions andkind support ; the NNSF of China for support of this work
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/219534
专题实验物理中心
粒子天体物理中心
推荐引用方式
GB/T 7714
Liu HB,Zheng YH,Xie YG,et al. Study of the THGEM detector with a reflective CsI photocathode[J]. 中国物理C,2011(4):363-367.
APA 刘宏邦.,郑阳恒.,谢一冈.,吕军光.,周莉.,...&郑志鹏.(2011).Study of the THGEM detector with a reflective CsI photocathode.中国物理C(4),363-367.