IHEP OpenIR  > 实验物理中心
Design and construction of the first prototype ionization chamber for CSNS and PA beam loss monitor (BLM) system
Xu MH(徐美杭); Tian JM(田建民); Chen C(陈昌); Chen YB(陈元柏); Xu TG(徐韬光); Lu ST(陆双桐)
2009
发表期刊中国物理C
期号2页码:123-126
通讯作者徐美杭
摘要Design and construction of the first prototype ionization chamber for CSNS and Proton Accelerator (PA) beam loss monitor (BLM) system is reported. The low leakage current (
关键词spallation neutron source proton accelerator beam loss monitor ionization chamber plateau curve linearity
项目资助者Supported by 973 Project (2007CB209904)
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/219324
专题实验物理中心
加速器中心
中国科学院高能物理研究所_中国散裂中子源
推荐引用方式
GB/T 7714
Xu MH,Tian JM,Chen C,et al. Design and construction of the first prototype ionization chamber for CSNS and PA beam loss monitor (BLM) system[J]. 中国物理C,2009(2):123-126.
APA 徐美杭,田建民,陈昌,陈元柏,徐韬光,&陆双桐.(2009).Design and construction of the first prototype ionization chamber for CSNS and PA beam loss monitor (BLM) system.中国物理C(2),123-126.
MLA 徐美杭,et al."Design and construction of the first prototype ionization chamber for CSNS and PA beam loss monitor (BLM) system".中国物理C .2(2009):123-126.