IHEP OpenIR  > 加速器中心
Beam induced vacuum measurement error in BEPC II
黄涛(加); XIAO Qiong; PENG XiaoHua; WANG HaiJing
2010
发表期刊Science China Press
页码4
通讯作者黄涛(加)
摘要When the beam in BEPCII storage ring aborts suddenly,the measured pressure of cold cathode gauges and ion pumps will drop suddenly and decrease to the base pressure gradually.This shows that there is a beam induced positive error in the pressure measurement during beam operation.The error is the ...
关键词BEPCⅡ vacuum measurement non-linear fitting measurement error negative exponential decay
文献类型期刊论文
条目标识符http://ir.ihep.ac.cn/handle/311005/217029
专题加速器中心
中国科学院高能物理研究所_中国散裂中子源
推荐引用方式
GB/T 7714
Huang T,XIAO Qiong,PENG XiaoHua,et al. Beam induced vacuum measurement error in BEPC II[J]. Science China Press,2010:4.
APA 黄涛,XIAO Qiong,PENG XiaoHua,&WANG HaiJing.(2010).Beam induced vacuum measurement error in BEPC II.Science China Press,4.
MLA 黄涛,et al."Beam induced vacuum measurement error in BEPC II".Science China Press (2010):4.